Low Voltage Aerial Bundle Cable

Low-voltage overhead insulated cables are mainly used to transmit power from distribution transformers to the customer end (e.g. residential homes, small commercial facilities, etc.). The insulation requirements are also relatively low, and insulating materials such as polyvinyl chloride (PVC) can be used at a relatively low cost, while also providing sufficient insulation protection against leakage and short-circuiting of low-voltage lines. The laying requirements of low-voltage overhead cables are relatively flexible and the safety distance requirements are relatively small. In some residential areas and other places, it can be laid closer to the building or ground under the premise of ensuring safety according to the actual situation, in order to facilitate the supply of electricity to the user terminal.

  1. STANDARD TAXNOMY
  • Cables are offered accords with GB/T 12527-2008.
  1. CONSTRUCTION
  • Conductor: Optional of copper wire, aluminum wire, aluminum alloy, and aluminum conductor steel reinforced
  • Number of Cores: 1, 2, 3, 4, 3+k (A), 3+k (B)
  • Nominal Cross Sectional Area/mm2: 10-400
  • Note: k is the neural conductor with bearing. (A) refers to steel bearing wire core, and (B) refers to  aluminum alloy bearing wire core. The cross section can be chosen for pairing up with the major core according to the requirements of the power distributing project.
  • Conductor screen: Extruded semiconducting layer
  • Insulation: Optional of Polyethylene(PE), Cross-Linked Polyethylene(XLPE) and Polyvinyl Chloride(PVC)
  1. APPLICATION
  • The products applies to the aerial electricity transmission and distribution line in the tall buildings, tourist attraction and forest zone.
  • The cable fit for aerial fixed-install-action, service entrance cable and so on.
  1. CHARACTERISTICS
  • Max. continuous temperature in operation:
  • PVC or PE insulated aerial cable: 70℃
  • HDPE insulated aerial cable: 75℃
  • XLPE insulated aerial cable: 90℃
  • Max. short-circuit temperature of the conductor (maximum duration: 5 seconds):
  • PVC insulated aerial cable: 160℃
  • PE insulated aerial cable: 130℃
  • HDPE insulated aerial cable: 150℃
  • XLPE insulated aerial cable: 250℃
  • Min. installation ambient temperature: -20℃.
  • Permissible bending radius of cable:
  • For cable diameter<25mm: No less than 4D
  • For cable diameter>25mm: No less than 6D
(Note: D-outer diameter of cable)

Parameter of some products

  • Type: CU/PVC, AL/PVC  0.6/1kV
No. of cores×nominal cross section
(mm2)
Insulator thickness
(mm)
Outer diameter
(mm)
Maximum DC resistance of conductor at 20℃
(Ω/km)
Copper Aluminum
1×10 1 6 1.83 3.08
1×16 1.2 8 1.15 1.91
1×25 1.2 9 0.727 1.2
1×35 1.4 10 0.524 0.868
1×50 1.4 11 0.387 0.641
1×70 1.4 13 0.268 0.443
1×95 1.6 15 0.193 0.32
1×120 1.6 17 0.153 0.253
1×150 1.8 19 0.124 0.206
1×185 2 21 0.0991 0.164
1×240 2.2 23 0.0754 0.125
1×300 2.2 25 0.0601 0.1
1×400 2.2 28 0.047 0.0778

Note: The above is only part of the product specifications and technical parameters, if you need detailed parameters, please contact our sales manager.

Annual Purchase in Chile (Contractor: Dartel S.A. Chile)

ENEL Project (Contractor: ENEL Distribucion PERU S.A.A)

Let’s Build The Future with Innovation

Please provide the following details to help our sales representatives better understand your needs and get In touch with you as soon as possible.