HLRHTCY(Z)-50-32M(75-1000MHZ)

ZTT offers a comprehensive copper leaky cable, capable of producing 1/2″, 7/8 “, 1-1/4”, 1-5/8 “. ZTT has won the single championship for leaky cable and has the first simulation tunnel testing system in China.

Product Advantages
  • High compatibility, low system loss
  • Efficiency &Convenience
  • Low field strength, uniform radiation
  • Convenient construction & engineering inspection
  • Rank: No.1 Brand in China

Construction of Cable

Item

Diameter(mm) Material
Inner conductor 13.1±0.3

Copper tube

Insulation

/ Foamed polyethylene
Outer copper conductor 33.6±0.3

Overlapping corrugated copper foil

Jacket

38.0±0.4

PE / LSZH flame retardant polyolefin

Mechanical Characteristics

Item

Unit Nominal value
Tensile strength N

≥2500

Min. static bending radius

mm 500 (Single bend)
Installation temperature

-25~+60 ℃

Operation temperature

-20~+85 ℃
Storage temperature

-55~+85 ℃

Electrical Characteristics

Item Specification
Characteristics impedance 50±2Ω
Velocity 88%
Min. insulation resistance 5000 MΩ·km
Operating Frequency 75175350500800900MHz
Dielectric strength 15000V( DC,1 min.)
Jacket spark test voltage 8000V(AC)
VSWR within working frequency band 1.3
Peak power 200kw
Coupling loss test direction ≤300MHz Radiation direction
≥300MHz Parallel direction

Note: The tolerance of VSWR shall be ±3%.

Attenuation

Frequency(MHz)

Attenuation (±5%)(dB/100m) Coupling loss

(50%/95%,2m)(±5dB)

75 0.78

53/62

100

0.85 52/62
150 1.06

53/68

175

1.20 55/68
300 1.62

60/67

350

1.97 57/60
400 2.15

56/59

450

2.17 56/60
800 3.62

53/62

900

4.10

54/64

Note: The tolerance of Attenuation shall be ±10%.The tolerance of Coupling loss shall be ±5dB.

 