In order to ensure the weather resistance of lightweight flexible components, transparent front plate products are introduced, capable to replace the front glass.The good vapor barrier ensures that the components can still maintain stable operation in wet environment;due to the high transmittance retention rate and perfect UV barrier, the transmittance retention rate is still high after various weather resistance tests, ensuring the long-term and efficient operation of the components.
Accompanied by the fluorine film independently developed by our company, the wear resistance and chalking resistance of the front plates have been effectively improved.
Product Features
Technical Indicators
|
No. |
Item | Unit | Value | Test Standard |
| 1 | Thickness | μm | 320±10% |
GB/T 13542.2-2021 |
|
2 |
Tensile strength(MD/TD) | Mpa | ≥100 | GB/T 1040.3-2006 |
| 3 | Elongation at break(MD/TD) | % | ≥100 |
GB/T 1040.3-2006 |
|
4 |
Dimensional stability (MD/TD) | % | MD≤ 1.0;TD≤ 0.7 | GB/T 13542.2-2021 |
| 5 | Peeling strength(MD/TD) | N/cm | ≥4 |
GB/T 2790-1995 |
|
6 |
Peeling strength with EVA | N/cm | ≥60 | GB/T 2790-1995 |
| 7 | Breakdown voltage | kV | ≥18 |
GB/T 1408.1-2016 |
|
8 |
Transmittance rate | % | ≥85(400-1100nm)
≤1(280-380nm) |
GB/T 2410-2008 |
| 9 | Water vapor permeability(38℃/90%RH) | g/m2·day | ≤1.5(electrolytic process) |
GB/T 21529-2008 |
|
10 |
Coating adhesion | level | 0 | GB/T 9286-2021 |
| 11 | Damp heat test (2000h)
UV aging test (500kWh/m2) Thermal cycle test (400 cycles) Humidity-freeze test(30 cycles) |
/
|
Appearance:no delamination, foaming, discoloration, crack, surface and adhesive layer not sticky
Δb≤3 Transmittance retention rate:≥95% Coating adhesion:level 0 Peeling strength:≥3N/cm |
IEC 61215-2021 |
Please provide the following details to help our sales representatives better understand your needs and get In touch with you as soon as possible.