ZTT offers a comprehensive copper leaky cable, capable of producing 1/2″, 7/8 “, 1-1/4”, 1-5/8 “. ZTT has won the single championship for leaky cable and has the first simulation tunnel testing system in China.
Cable Type: HLRCACY(Z)-50-12T
|
Electrical Specifications |
||
| Impedance | Ohm |
50±2 |
|
Velocity |
% | 88 |
| Capacitance | pF/m |
76 |
|
Stop bands |
MHz |
1200-1400,2025~2110,2300~2400 |
Mechanical Characteristics
| Jacket Material | PE / LSZH flame retardant polyolefin | |
| Inner Conductor Material | Copper clad aluminum wire | |
| Outer Conductor Material | Overlapping corrugated copper foil | |
| Diameter Inner Conductor | mm | 4.80±0.05 |
| Diameter Outer Conductor | mm | 13.00±0.30 |
| Diameter over Jacket | mm | 15.60±0.30 |
| Minimum Bending Radius, Single Bend | mm | 200(Single bend) |
| Tensile Force | N | 1100 |
| VSWR | 1700-2025MHz | ≤1.30 |
| 2110-2700MHz | ≤1.30 | |
| 3300-3700MHz | ≤1.40 | |
| 4800-5000MHz | ≤1.40 | |
| Recommended Clamp Spacing | m | 0.9 |
| Minimum Distance to Wall | mm | 80 |
| Temperature Specifications | ||
|
Installation temperature |
℃ | -25~+60 ℃ |
| Operation temperature | ℃ |
-20~+85 ℃ |
|
Storage temperature |
℃ |
-55~+85 ℃ |
|
Frequency(MHz) |
Attenuation(dB/100m) | Coupling loss
(50%/95%,2m) |
| 600 | 6.13 |
88/97 |
|
700 |
6.68 | 87/96 |
| 800 | 7.22 |
86/95 |
|
850 |
7.44 | 84/90 |
| 900 | 7.71 |
79/89 |
|
1000 |
7.96 | 76/86 |
| 1200 | 9.06 |
76/86 |
|
1400 |
9.94 | 75/85 |
| 1500 | 10.35 |
75/85 |
|
1700 |
11.11 | 70/84 |
| 1800 | 11.50 |
69/75 |
|
1900 |
11.93 | 66/77 |
| 2000 | 12.34 |
73/83 |
|
2100 |
12.67 | 77/86 |
| 2300 | 13.39 |
74/83 |
|
2400 |
13.76 | 74/84 |
| 2500 | 14.17 |
75/83 |
|
2600 |
14.48 | 75/82 |
| 2700 | 14.85 |
75/83 |
|
3000 |
16.22 | 75/81 |
| 3300 | 17.00 |
71/80 |
|
3400 |
17.31 | 70/79 |
| 3500 | 17.74 |
71/79 |
|
3600 |
17.94 | 71/79 |
| 3700 | 18.41 |
71/79 |
|
3800 |
18.74 | 70/78 |
| 4000 | 19.50 |
70/78 |
|
4200 |
20.81 | 70/78 |
| 4400 | 21.53 |
69/77 |
|
4600 |
22.41 | 69/77 |
| 4800 | 23.62 |
68/77 |
|
5000 |
25.20 | 68/76 |
| 5400 | 26.72 |
66/74 |
|
5800 |
30.16 | 66/74 |
| 6000 | 32.42 |
65/74 |
Note: The tolerance of Coupling loss shall be ±5dB,and the tolerance of Attenuation shall be ±10%.
Please provide the following details to help our sales representatives better understand your needs and get In touch with you as soon as possible.
Connecting the World
Powering the Future
Products
Quick Link