Medium Voltage Aerial Bundle Cable

Medium Voltage Aerial Bundle Cable utilize cross-linked polyethylene (XLPE) to ensure high electrical and thermal endurance, making them suitable for distributing power from substations to distribution transformers in urban grids.

Product Advantages
  1. Insulated & Integrated Design
XLPE insulation ensures excellent electrical and thermal endurance in a bundled, space-saving structure.
  1. Durable & Safe Overhead
High mechanical stability and reliable insulation offer superior safety and weather resistance for long-term use.
  1. Cost-Effective & Adaptable
Low erection and maintenance costs, adaptable to areas with limited clearances or tree contact.
  1. STANDARD TAXNOMY

Cables are offered accords with GB/T 14049-2008.

  1. CONSTRUCTION

Conductor: Optional of copper wire, aluminum wire, aluminum alloy, and aluminum conductor steel reinforced

Number of Cores: 1, 3, 3+k (A), 3+k (B)

Nominal Cross Sectional Area/mm2: 10-400

Note: k is the neural conductor with bearing. (A) refers to steel bearing wire core, and (B) refers to  aluminum alloy bearing wire core. The cross section can be chosen for pairing up with the major core according to the requirements of the power distributing project.

Conductor screen: Extruded semiconducting layer

Insulation: Optional of Polyethylene(PE), Cross-Linked Polyethylene(XLPE) and Polyvinyl Chloride(PVC)

  1. CHARACTERISTICS

Max. continuous temperature in operation:

PVC or PE insulated aerial cable: 70℃

HDPE insulated aerial cable: 75℃

XLPE insulated aerial cable: 90℃

Max. short-circuit temperature of the conductor (maximum duration: 5 seconds):

PVC insulated aerial cable: 160℃

PE insulated aerial cable: 130℃

HDPE insulated aerial cable: 150℃

XLPE insulated aerial cable: 250℃

Min. installation ambient temperature: -20℃.

Permissible bending radius of cable:

For single core cable: No less than 20(D+d)

For multiple cores cable: No less than 15(D+d)

(Note: D-outer diameter of cable, d-outer diameter of conductor)

The products applies to the aerial electricity transmission and distribution line in the tall buildings, tourist attraction and forest zone.

The distance between the cable and trees should be taken into account, when the cable is laid in the aerial. It is permissible that the cable contact with trees.