Flame-retardant and fire-resistance optical cables can control the spread of fire during a fire and maintain the integrity of the communication line.
GYHTZSH58-FR
| No of Fiber | Cable diameter ±0.5(mm) |
Cable weight ±15% (kg/km) |
Tensile load (N) | Crush load (N/100mm) |
| 12 | 15.3 | 273 | 1000/3000 | 1000/3000 |
| 24 | 15.3 | 274 | 1000/3000 | 1000/3000 |
| 48 | 15.6 | 285 | 1000/3000 | 1000/3000 |
| 96 | 17.6 | 343 | 1000/3000 | 1000/3000 |
GYFHTH-FR
| No of Fiber | Cable diameter ±0.5(mm) |
Cable weight ±15% (kg/km) |
Tensile load (N) | Crush load (N/100mm) |
| 2-36 | 10.1 | 75 | 600/1500 | 300/1000 |
| 38-72 | 10.1 | 76 | 600/1500 | 300/1000 |
| 74-84 | 10.8 | 89 | 600/1500 | 300/1000 |
| 86-96 | 11.4 | 97 | 600/1500 | 300/1000 |
| 98-108 | 12.1 | 108 | 600/1500 | 300/1000 |
| 110-120 | 12.7 | 119 | 600/1500 | 300/1000 |
| 122-132 | 13.4 | 132 | 600/1500 | 300/1000 |
| 134-144 | 14 | 145 | 600/1500 | 300/1000 |
| 146-216 | 14.1 | 144 | 600/1500 | 300/1000 |
| 218-240 | 14.8 | 161 | 600/1500 | 300/1000 |
| 242-264 | 15.4 | 173 | 600/1500 | 300/1000 |
| 266-288 | 16.1 | 188 | 600/1500 | 300/1000 |
GYMXTPH-FR
| No of Fiber | Cable diameter ±0.5(mm) |
Cable weight ±15% (kg/km) |
Tensile load (N) | Crush load (N/100mm) |
| 1-2 | 5 | 68 | 600/1500 | 300/1000 |
| 4-12 | 5.6 | 80 | 600/1500 | 300/1000 |
| 16-24 | 6 | 86 | 600/1500 | 300/1000 |
| 28-30 | 6.4 | 92 | 600/1500 | 300/1000 |
| 36-48 | 6.8 | 103 | 600/1500 | 300/1000 |
| 56-72 | 7.3 | 110 | 600/1500 | 300/1000 |
| 84-96 | 7.6 | 118 | 600/1500 | 300/1000 |